This selector is a tool to help with the selection of modular frames, modules, and contacts. The Insert Summary provides a list of all part numbers for both male and female inserts based on the selections made on the Input Form. There are links for the hoods and bases next to the frame summary to help with the housing selection. The configurator includes some cross-checks to prevent incorrect selections, however, the final selections are the responsibility of the person using the configurator and should be verified against the catalog Here
is how to begin using the selector: |
|
|
|
| MODULE SUMMARY FOR EASIER SELECTION | |||||
| Modules | Termination | Rated Voltage | Rated Amp | AWG Sizes | Notes |
| 2 Contact Module: 2 Working Contacts | Screw | 1000V | 82A | 4, 6, 8, 10, 12 | Fills 2 Positions, Use High Profile Housing, Use with Ground Module |
| 2 Contact Module: 1 Working Contact & Ground | Screw | 1000V | 82A | 4, 6, 8, 10, 12 | Fills 2 Positions, Use High Profile Housing, Mount in first position by ground screw |
| 3 Contact Coax Module | Crimp | 250V | - | RG 58 | |
| 3 Contact Module | Crimp | 630V | 40A | 8, 10, 12, 14, 16 | |
| 3 Contact High Voltage Module | Crimp | 1000V | 50A | 8, 10, 12, 14, 16 | |
| 4 Contact Module | Crimp | 630V | 25A | 12, 14, 16, 18, 20 | |
| 4+PE Contact High Voltage Module | Crimp | 1000V | 16A | 12, 14, 16, 18, 20 | |
| 5 Contact Module | Crimp | 400V | 20A | 12, 14, 16, 18, 20 | |
| 10 Contact Module: Stamped & Formed | Crimp | 250V | 10A | 14, 16, 18, 20, 22, 24, 26 | |
| 10 Contact Module: Crimp Machine | Crimp | 250V | 10A | 14, 16, 18, 20, 22, 24, 26 | |
| 20 Contact Module | Crimp | 100V | 4A | 20, 22, 24, 26 | |
| Dummy Module | NA | - | - | NA | |
| 4 Contact Cage Clamp Module | Screw | 400V | 14A | 14, 16, 18, 20 | |
| Ethernet Module: RJ 45 Connectors + 4 Power Contacts | Crimp | 600V | 10A | 14, 16, 18, 20, 22, 24, 26 | Fills 2 positions, Requires RJ 45 plug and up to 4 power contacts |
| Profibus DP Module: 2 Contacts + Shield | NA | 30V | 1A | 20, 22, 24 | Use High Profile Housing; mount on far end of frame without ground screw |
Search Results |
| FRAMES | ||||
| # of Modules | Male Part Number | Female Part Number | Housing | |
| MODULES (FRAME # 1) | ||||
Module Type |
Male Part Number |
Female Part Number |
||
| CONTACTS (FRAME # 1) | |||||
Wire Gauge |
Male Part Number | Module | Female Part Number | Max. Qty per Module | Termination Type |